Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Avances en Odontoestomatologia ; 39(1):42-48, 2023.
Article in Spanish | EMBASE | ID: covidwho-20234681

ABSTRACT

The oral cavity houses a large number of microorganisms that are potential pathogens, such as cytome-galovirus, hepatitis B virus (HBV), hepatitis C virus, herpes simplex virus types 1 and 2, human immuno-deficiency virus, mycobacterium tuberculosis and currently with the appearance of the SARS COV-2 that causes covid-19, the dental community must take stricter measures in its protection protocols against diseases. To evaluate its germicidal efficacy, ultraviolet light was applied with different exposure times on the alginate dental impressions, immediately after having taken the impression, which when it came into contact with the oral cavity of the patient is contaminated. As a result, a decrease in size and quantity of the bacterial colonies was observed in most of the samples in which the UV LED light was applied at 10 and 15 minutes of exposure. Some samples showed less bacterial growth even after 5 minutes of exposure. All this confirms its germicidal capacity thanks to its 245 nm ultraviolet spectrum that affects the DNA and RNA chain of microorganisms since it is the wavelength of maximum absorption of its molecule, eliminating its reproductive and survival capacity. The advantages it offers such as its small size, easy to handle and install, that it does not require constant maintenance, low acquisition cost;its constant high intensity light that does not generate any increase in temperature, makes it an excellent disinfectant auxiliary that can be incorporated into dental clinics.Copyright © 2023, Ediciones Avances S.L.. All rights reserved.

2.
Environ Int ; 177: 108022, 2023 07.
Article in English | MEDLINE | ID: covidwho-20231002

ABSTRACT

A non-filter virus inactivation unit was developed that can control the irradiation dose of aerosolized viruses by controlling the lighting pattern of a 280 nm deep-UV (DUV)-LED and the air flowrate. In this study, the inactivation properties of aerosolized SARS-CoV-2 were quantitatively evaluated by controlling the irradiation dose to the virus inside the inactivation unit. The RNA concentration of SARS-CoV-2 remained constant when the total irradiation dose of DUV irradiation to the virus exceeded 16.5 mJ/cm2. This observation suggests that RNA damage may occur in regions below the detection threshold of RT-qPCR assay. However, when the total irradiation dose was less than 16.5 mJ/cm2, the RNA concentration monotonically increased with a decreasing LED irradiation dose. However, the nucleocapsid protein concentration of SARS-CoV-2 was not predominantly dependent on the LED irradiation dose. The plaque assay showed that 99.16% of the virus was inactivated at 8.1 mJ/cm2 of irradiation, and no virus was detected at 12.2 mJ/cm2 of irradiation, resulting in a 99.89% virus inactivation rate. Thus, an irradiation dose of 23% of the maximal irradiation capacity of the virus inactivation unit can activate more than 99% of SARS-CoV-2. These findings are expected to enhance versatility in various applications. The downsizing achieved in our study renders the technology apt for installation in narrow spaces, while the enhanced flowrates establish its viability for implementation in larger facilities.


Subject(s)
COVID-19 , Viruses , Humans , SARS-CoV-2 , Disinfection/methods , Ultraviolet Rays , RNA
3.
J Hosp Infect ; 135: 11-17, 2023 May.
Article in English | MEDLINE | ID: covidwho-2220982

ABSTRACT

BACKGROUND: Ultraviolet (UV)-light-emitting diodes (UV-LEDs) are energy efficient and of special interest for the inactivation of micro-organisms. In the context of the coronavirus disease 2019 pandemic, novel UV technologies can offer a powerful alternative for effective infection prevention and control. METHODS: This study assessed the antimicrobial efficacy of UV-C LEDs on Escherichia coli, Pseudomonas fluorescens and Listeria innocua, as well as severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2), human immunodeficiency virus-1 (HIV-1) and murine norovirus (MNV), dried on inanimate surfaces, based on European Standard EN 17272. RESULTS: This study found 90% inactivation rates for the tested bacteria at mean UV-C doses, averaged over all three investigated UV-C wavelengths, of 1.7 mJ/cm2 for E. coli, 1.9 mJ/cm2 for P. fluorescens and 1.5 mJ/cm2 for L. innocua. For the tested viruses, UV doses <15 mJ/cm2 resulted in 90% inactivation at wavelengths of 255 and 265 nm. Exposure of viruses to longer UV wavelengths, such as 275 and 285 nm, required much higher doses (up to 120 mJ/cm2) for inactivation. Regarding inactivation, non-enveloped MNV required much higher UV doses for all tested wavelengths compared with SARS-CoV-2 or HIV-1. CONCLUSION: Overall, the results support the use of LEDs emitting at shorter wavelengths of the UV-C spectrum to inactivate bacteria as well as enveloped and non-enveloped viruses by exposure to the appropriate UV dose. However, low availability and excessive production costs of shortwave UV-C LEDs restricts implementation at present, and supports the use of longwave UV-C LEDs in combination with higher irradiation doses.


Subject(s)
Anti-Infective Agents , COVID-19 , Norovirus , Viruses , Humans , Animals , Mice , Escherichia coli , SARS-CoV-2 , Ultraviolet Rays , Bacteria , Disinfection/methods , Virus Inactivation
4.
J Hazard Mater Adv ; 8: 100183, 2022 Nov.
Article in English | MEDLINE | ID: covidwho-2178972

ABSTRACT

The COVID-19 pandemic highlighted public awareness of airborne disease transmission in indoor settings and emphasized the need for reliable air disinfection technologies. This increased awareness will carry in the post-pandemic era along with the ever-emerging SARS-CoV variants, necessitating effective and well-defined protocols, methods, and devices for air disinfection. Ultraviolet (UV)-based air disinfection demonstrated promising results in inactivating viral bioaerosols. However, the reported data diversity on the required UVC doses has hindered determining the best UVC practices and led to confusion among the public and regulators. This article reviews available information on critical parameters influencing the efficacy of a UVC air disinfection system and, consequently, the required dose including the system's components as well as operational and environmental factors. There is a consensus in the literature that the interrelation of humidity and air temperature has a significant impact on the UVC susceptibility, which translate to changing the UVC efficacy of commercialized devices in indoor settings under varying conditions. Sampling and aerosolization techniques reported to have major influence on the result interpretation and it is recommended to use several sampling methods simultaneously to generate comparable and conclusive data. We also considered the safety concerns and the potential safe alternative of UVC, far-UVC. Finally, the gaps in each critical parameter and the future research needs of the field are represented. This paper is the first step to consolidating literature towards developing a standard validation protocol for UVC air disinfection devices which is determined as the one of the research needs.

5.
Environ Int ; 170: 107580, 2022 Dec.
Article in English | MEDLINE | ID: covidwho-2068945

ABSTRACT

A general-purpose virus inactivation unit that can inactivate viruses was developed using deep ultraviolet (DUV) LEDs that emit DUV rays with a wavelength of 280 nm. The inside of the virus inactivation unit is a rectangular conduit with a sharp turn of 180° (sharp-turned rectangular conduit). Virus inactivation is attempted by directly irradiating the air passing through the conduit with DUV rays. The flow characteristics of air and virus particles inside the virus inactivation unit were investigated using numerical simulations. The air was locally accelerated at the sharp turn parts and flowed along the partition plate in the sharp-turned rectangular conduit. The aerosol particles moving in the sharp-turned rectangular conduit were greatly bent in orbit at the sharp turn parts, and then rapidly approached the partition plate at the lower part of the conduit. Consequently, many particles collided with the partition plates behind the sharp-turn parts. SARS-CoV-2 virus was nebulized in the virus inactivation unit, and the RNA concentration and virus inactivation rate with and without the emission of DUV-LEDs were measured in the experiment. The concentration of SARS-CoV-2 RNA was reduced to 60% through DUV-LED irradiation. In addition, SARS-CoV-2 passing through the virus inactivation unit was inactivated below the detection limit by the emission of DUV-LEDs. The virus inactivation rate and the value of the detection limit corresponded to 99.38% and 35.36 TCID50/mL, respectively.

6.
IEEE International Instrumentation and Measurement Technology Conference (I2MTC) ; 2021.
Article in English | Web of Science | ID: covidwho-1978392

ABSTRACT

LED lighting is becoming increasingly pervasive in many areas ranging from ambient lighting, up to applications such as microscope illumination, UV-LED curing and, UV disinfection for air, surfaces, and water. Irradiance uniformity is often a fundamental parameter for guiding the design, comparison, and optimization of the illuminator. To this end, many methods and procedures have been proposed to guide the arrangement of the LED sources, as well as to guide the design of ad-hoc lenses. Nevertheless, there are many applications in which it is important to be able to consider other aspects as well as the uniformity of the irradiance. For this purpose, we propose both a method that allows calculating the irradiance generated by the used LED sources and, performance indicators for guiding the design and comparing different optical layouts.

7.
Sensors (Basel) ; 22(13)2022 Jun 27.
Article in English | MEDLINE | ID: covidwho-1934197

ABSTRACT

Nowadays, the disinfection of classrooms, shopping malls, and offices has become an important part of our lives. One of the most effective disinfection methods is ultraviolet (UV) radiation. To ensure the disinfection device has the required wavelength spectrum, we need to measure it with dedicated equipment. Thus, in this work, we present the development of a UV spectrum detector capable of identifying UV wavelength spectrums, with a wide range of probes and the ability to transmit data to a PC for later evaluation of the results. The device was developed with four UV sensors: one for UV-A, one for UV-B, one for UV-C, and one with a wide range of detection of UVA, with a built-in transimpedance amplifier. An Arduino Nano development board processes all the acquired data. We developed a custom light source containing seven UV LEDs with different central wavelengths to calibrate the device. For easy visualization of the results, custom PC software was developed in the Processing programming medium. For the two pieces of electronics-the UV detector and calibration device-3D-printed housings were created to be ergonomic for the end-user. From the price point of view, this device is affordable compared to what we can find on the market.


Subject(s)
Water Purification , Disinfection/methods , Electronics , Light , Ultraviolet Rays , Water Purification/methods
8.
Pathogens ; 10(6)2021 Jun 15.
Article in English | MEDLINE | ID: covidwho-1270099

ABSTRACT

More than 1 year has passed since social activities have been restricted due to the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). More recently, novel SARS-CoV-2 variants have been spreading around the world, and there is growing concern that they may have higher transmissibility and that the protective efficacy of vaccines may be weaker against them. Immediate measures are needed to reduce human exposure to the virus. In this study, the antiviral efficacy of deep-ultraviolet light-emitting diode (DUV-LED) irradiation (280 ± 5 nm, 3.75 mW/cm2) against three SARS-CoV-2 variants was evaluated. For the B.1.1.7, B.1.351, and P.1 variant strains, irradiation of the virus stocks for 1 s resulted in infectious titer reduction rates of 96.3%, 94.6%, and 91.9%, respectively, and with irradiation for 5 s, the rates increased to 99.9%, 99.9%, and 99.8%, respectively. We also tested the effect of pulsed DUV-LED irradiation (7.5 mW/cm2, duty rate: 50%, frequency: 1 kHz) under the same output conditions as for continuous irradiation and found that the antiviral efficacy of pulsed and continuous irradiation was the same. These findings suggest that by further developing and optimizing the DUV-LED device to increase its output, it may be possible to instantly inactivate SARS-CoV-2 with DUV-LED irradiation.

9.
Emerg Microbes Infect ; 9(1): 1744-1747, 2020 Dec.
Article in English | MEDLINE | ID: covidwho-653863

ABSTRACT

The spread of novel coronavirus disease 2019 (COVID-19) infections worldwide has raised concerns about the prevention and control of SARS-CoV-2. Devices that rapidly inactivate viruses can reduce the chance of infection through aerosols and contact transmission. This in vitro study demonstrated that irradiation with a deep ultraviolet light-emitting diode (DUV-LED) of 280 ± 5 nm wavelength rapidly inactivates SARS-CoV-2 obtained from a COVID-19 patient. Development of devices equipped with DUV-LED is expected to prevent virus invasion through the air and after touching contaminated objects.


Subject(s)
Betacoronavirus/radiation effects , Coronavirus Infections/virology , Pneumonia, Viral/virology , Animals , Betacoronavirus/isolation & purification , COVID-19 , Cell Survival , Chlorocebus aethiops , Decontamination , Humans , Pandemics , SARS-CoV-2 , Ultraviolet Rays , Vero Cells , Virus Inactivation
SELECTION OF CITATIONS
SEARCH DETAIL